Skip to content
Security FilmGuide

8 mil vs 14 mil vs 24 mil security film: what thickness can tell you

Thickness is a measurement, not a protection rating — and manufacturers do not all measure the same thing.

By Shore Tint & More editorial team · · 7 min read

Official sources checked . Procurement pages change; confirm with the agency.

Key takeaways

  • One mil is one thousandth of an inch; it is a unit, not a performance class.
  • 3M lists S2400 at 25 mil (635 µm) with adhesive in its data sheet and 24 mil (610 µm) in a physical properties bulletin; LLumar PS13 is 0.013 in (13 mil).
  • S140 is 14 mil nominal and is not approved for windstorm or blast mitigation, despite its thickness.
  • No universal ladder (8 residential, 14 commercial, 24 schools) follows from the documents.

Mil is a unit, not a protection rating

One mil is 0.001 inch. Exact conversions are arithmetic, not statements about any manufacturer's tolerances or rounded datasheet values:

Exact unit conversions
MilInchesMillimeters (exact)
8 mil0.008 in0.2032 mm
14 mil0.014 in0.3556 mm
24 mil0.024 in0.6096 mm

Datasheets round: LLumar lists PS8 at 200 µm and S800's sheet lists 8 mil as 203 µm. Neither rounding is an error; just copy the figure the document gives.

Compare like with like

A product label, the nominal film thickness and the total including adhesive can be three different numbers. Before comparing quotes, copy the manufacturer's label exactly and record what it measures.

Thickness as stated, with its basis
ProductFigure as statedWhat the figure measuresSource
3M Ultra S8008 mil (203 µm) / 9 mil (230 µm)Nominal film / total with adhesiveS800 Rev. G
3M Safety S14014 milNominal film; no separate adhesive-inclusive figure statedS140 Rev. D
3M S2400 (data sheet)25 mil (635 µm)With adhesiveS2400 data sheet, April 2025
3M S2400 (physical properties bulletin)24 mil (610 µm)Not labeled in the bulletin; do not treat as adhesive-inclusiveS2400 physical properties, Rev. A, April 2025
XPEL Security Clear 14mil14 milNominal film; adhesive-inclusive figure not statedXPEL specification
LLumar SCL SR PS8 / PS130.008 in (200 µm) / 0.013 in (325 µm)Basis not stated on the sheetLLumar properties sheet
Solar Gard Armorcoat 14 mil Clear (UK/EU)350 / 400 µmLabeled nominal / overall; the sheet does not say the difference is adhesive aloneArmorcoat sheet

Where a sheet does not establish a basis, that belongs on the clarification list, not in a guessed column. S2400 shows why: 3M's bulletin calls it 24 mil (610 µm) and its data sheet 25 mil (635 µm) with adhesive. Those are different figures, not a contradiction to resolve by rounding, so a quote saying "24 mil S2400" should state which document and basis it uses. A "24 mil" figure from any other product still needs a product code and basis before it means anything.

Thickness does not replace the rest of the specification

Use the product code, construction, glass substrate, attachment and test documentation together. A thicker number can conceal a change in material — S2400 is polyurethane, S800 and S140 are polyester — or in how the system is installed. S140 shows the point: at 14 mil nominal it is thicker than S800, yet its specifications state it is not approved for windstorm or blast mitigation applications, while S800's list IPA-attached windstorm and explosion testing on named glass.

Nor does a larger number establish ballistic performance or a guaranteed delay time. 3M states its films are not bulletproof and not designed to stop intruders. Ballistic systems are a separate, assembly-specific category; see security film vs ballistic glazing.

Compare documented systems, not numbers.

Use the locator to find listed providers for your area, and ask each for the product code, thickness basis and test documents.

See listed providers by area →

Glass, film and whole-unit thickness are different numbers

Three thicknesses often get mixed up: the film, each lite of glass, and the whole insulating unit. A ½-inch insulating unit made of two lites and an air space is not ½ inch of continuous glass, and cavity or plies cannot be summed to meet a minimum continuous-glass requirement. The C-Bond seller's FAQ makes this point about its BRS system, which relies on ½-inch annealed glass.

Film thickness behaves the same way. One thicker film and several stacked thinner films are different constructions with different performance and approval status. A documented system such as C-Bond BRS's multilayer stack is tested and described as its own system; it is not permission to layer films arbitrarily. See C-Bond Secure vs BRS.

Material matters too. S2400 is polyurethane; S800 and S140 are polyester. Compare matched test reports for the intended use, not nominal thickness or tensile figures alone; how to read a test report explains what to match.

Two procurement examples

Incomplete: "Install 24 mil security film on all ground-floor windows." There is no product code, no thickness basis, no glass survey, no attachment and no report. It cannot be compared or approved.

More complete: "3M Ultra S800 (8 mil nominal per Rev. G), with 3M IPA on the surveyed openings listed, for break-and-entry use, with the report for the intended application attached." That is easier to evaluate, but it is not automatically better than another documented proposal; it still has to match the actual glass, frame and objective.

A practical purchase worksheet

For each opening group, record:

  • Target use (fragment retention, forced-entry delay, windstorm, other).
  • Exact product code and document revision.
  • Thickness as stated, with its basis.
  • Observed glass type and thickness, and frame.
  • Proposed attachment and edge detail.
  • Supporting test report and how its configuration compares.
  • Installation scope and warranty documents.

Mark unresolved items, and approve the documented assembly rather than a thickness number. The brand comparison guide lists the bidder questions.

Frequently asked questions

Is 24 mil always the right choice?

No recommendation follows from thickness. Ask the project team to justify the specified system for the actual glazing and objective.

Are two 14 mil products equivalent?

A thickness label does not establish equivalence. Compare current documentation and matching test configurations.

Is 8 mil film only for homes?

No such rule appears in the documents reviewed; S800's specifications list commercial applications with IPA attachment. This site covers commercial and institutional buildings only.

Sources

These guides began as AI-assisted drafts from the Shore Tint & More editorial team. Our guides explain product documentation and practical project planning. Manufacturer test claims are linked, and site-specific recommendations require an assessment. Spotted an error? Contact us for corrections.